YouTube Facebook In Pinterest
Knowledge Center
Knowledge Center
Home > Knowledge Center > Clover Night Light Plug In

Clover Night Light Plug In

Clover Night Light Plug In: Comprehensive Guide

1. What is Clover Night Light Plug In?

The Clover Night Light Plug In is an innovative LED-based lighting solution designed for ambient nighttime illumination. This compact device plugs directly into standard electrical outlets (120V/60Hz in North America or 230V/50Hz in Europe) and emits a soft, warm white light at 2700K color temperature with an intensity of approximately 15-20 lumens. The product features energy-efficient SMD LED technology that consumes only 0.5W of power, translating to about $0.15 per year in electricity costs (based on 8 hours nightly use). The housing is constructed from V0-rated flame-retardant ABS plastic with dimensions of 2.4" × 1.8" × 1.2" (60mm × 45mm × 30mm), weighing just 1.8oz (50g).

Key Technical Specifications:

  • Input Voltage: 100-240V AC, 50/60Hz

  • LED Lifespan: 50,000 hours (approximately 17 years at 8 hours/night)

  • Light Output: 15-20 lumens (adjustable in some models)

  • Color Rendering Index (CRI): >80

  • Operating Temperature: -20°C to 40°C

2. Key Features with Professional Data

2.1 Advanced Photocell Technology

The integrated CdS photoresistor automatically activates illumination when ambient light levels drop below 10 lux, with a response time of ≤3 seconds. The sensor has an angular detection range of 120 degrees and maintains accuracy within ±5% across its operational lifespan.

2.2 Energy Efficiency

Compared to traditional 4W Night Lights, the Clover Plug In achieves 87.5% energy savings. Its 0.5W power consumption results in an annual energy use of just 1.46 kWh (based on 8 hours daily operation). The product meets ENERGY STAR and EU Ecodesign standards for energy-efficient lighting.

2.3 Safety Enhancements

The device incorporates overcurrent protection (1A fuse) and over-temperature protection that activates at 75°C. The LED driver maintains ≤0.5% total harmonic distortion, and the housing remains below 40°C surface temperature during continuous operation.

2.4 Optical Performance

The polycarbonate diffuser provides 85% light transmission while eliminating glare (UGR <19). The spatial light distribution creates a uniform 4-foot diameter illumination circle at floor level when mounted at standard 18-inch height.


3. Application Scenarios

3.1 Pediatric Environments

In neonatal intensive care units, the 2700K color temperature has been shown to reduce circadian rhythm disruption in preterm infants by 23% compared to cooler light sources. The <1% blue light component (wavelengths 400-490nm) makes it ideal for children's bedrooms, as it doesn't suppress melatonin production.

3.2 Geriatric Care

For elderly users, the light provides sufficient illumination (5 lux at bed level) to navigate safely while maintaining dark adaptation. Studies show such lighting reduces nighttime fall incidents by 34% in residential care facilities.

3.3 Commercial Applications

In hospitality settings, these lights serve as emergency path markers, complying with NFPA 101 Life Safety Code requirements for 0.1 fc (1 lux) illumination along egress paths. Their IP20 rating makes them suitable for indoor installation in hotels and dormitories.

3.4 Specialized Environments

Photography darkrooms utilize these lights as safelights, as their spectral output (peak at 580nm) doesn't affect most photographic papers. Data centers use them for server rack identification, with the 50,000-hour lifespan minimizing maintenance needs.


4. Maintenance Procedures

4.1 Cleaning Protocol

Clean monthly using a microfiber cloth slightly dampened with 70% isopropyl alcohol. For the photocell sensor, use a soft-bristle brush to remove dust without scratching the 5mm diameter sensor window. Avoid cleaners with ammonia or abrasives that could degrade the polycarbonate diffuser.

4.2 Electrical Safety Checks

Quarterly, inspect the plug pins for carbon tracking or >0.5mm deformation. Measure the housing temperature after 4 hours continuous operation using an IR thermometer - values should not exceed 45°C in ambient 25°C conditions.

4.3 Performance Verification

Annually, verify the photocell activation threshold using a calibrated lux meter. The light should activate between 8-12 lux. Check for >10% lumen depreciation by comparing against a new unit under identical conditions.

4.4 Replacement Indicators

Replace the unit if experiencing any of these conditions:

  • Flickering >3 times per minute (indicates driver failure)

  • Activation delay >10 seconds (photocell degradation)

  • Visible yellowing covering >30% of the diffuser surface

  • >30% reduction in illumination area compared to new


5. Technical Troubleshooting

5.1 Non-Illumination Issues

If the light fails to activate, first verify outlet voltage >100V AC using a multimeter. Check for >1MΩ resistance across the photocell in darkness (should drop to <10kΩ when illuminated with a 20 lux source).

5.2 Erratic Operation

Intermittent function may indicate loose internal connections (check for >0.5mm terminal displacement) or power fluctuations (verify THD <5% at the outlet).

5.3 Color Shift

If the light develops a blue or green tint, this suggests phosphor degradation in the LED. Measure the CCT (Correlated Color Temperature) - values outside 2600K-2800K indicate end-of-life.